Valve Plates. The
ones on the left showing cracking and port damage. This can be
caused by hydraulic shock or cavitation. Plate face wear is
commonly caused by contaminated fluid (i.e.dirt).
hydraulic pump valve hydraulic parts
hydraulic part hydraulic machines hydraulic actuators hydraulic
valves hydraulic repair pump repair